3D-Conformal versus Intensity modulated radiation therapy in the treatment of early stage glottic squamous cell carcinoma: A dosimetrical analysis
Abstract
Background: The objective of this study is to dosimetrically compare and contrast both techniques in the treatment of early stage glottic squamous cell carcinoma as regards the planning dose volume (PTV) dose coverage and the doses perceived by the organs at risk particularly the thyroid gland, carotid arteries and spinal cord. Methods: Twenty patients with the pathological diagnosis of early glottic SCC (T1-T2/N0) were enrolled in the study design during the period October 2022 till January 2023. All patients were treated in Kasr Elainy center of clinical oncology using 3D-CRT radiotherapy technique. A dose of 66Gy in 33 fractions was the prescribed dose to the planning target volume (PTV). An intensity modulated radiotherapy (IMRT) plan was done for each patient and the dosimetric parameters were contrasted to the 3D-CRT plan Results: The homogeneity index (HI) for PTV66Gy was higher for the IMRT plans with a value of 0.1± 0.005 as contrasted to 0.08 ± 0.006 for the 3D-CRT plans with a statistically significant p-value of 0.002. The IMRT plans showed z significantly superior PTV95% coverage with values of 98.3 ± 14.7 as opposed to 94.5 ± 30.7 for the 3D-CRT plans (p-value of 0.003). The dose received by the thyroid gland was lower in the IMRT group with a value of 14.9Gy ± 5.39 compared to 51.2Gy ± 8.62 for the 3D-CRT plans with a statistically significant p-value of 0.004. Mean doses to the right and left carotid artery were lower in the IMRT plans compared to the 3D-CRT plans (p-value of 0.201& 0.266). Conclusion: In early glottic cancer, the plans generated by IMRT showed a better PTV coverage and more homogeneous dose distribution when compared to the plans achieved by 3D-CRT. The IMRT plans showed better OAR sparing with respect to the thyroid gland and carotid arteries.
(2023). 3D-Conformal versus Intensity modulated radiation therapy in the treatment of early stage glottic squamous cell carcinoma: A dosimetrical analysis. SECI Oncology Journal, 11(2), 146-152.
MLA
. "3D-Conformal versus Intensity modulated radiation therapy in the treatment of early stage glottic squamous cell carcinoma: A dosimetrical analysis", SECI Oncology Journal, 11, 2, 2023, 146-152.
HARVARD
(2023). '3D-Conformal versus Intensity modulated radiation therapy in the treatment of early stage glottic squamous cell carcinoma: A dosimetrical analysis', SECI Oncology Journal, 11(2), pp. 146-152.
VANCOUVER
3D-Conformal versus Intensity modulated radiation therapy in the treatment of early stage glottic squamous cell carcinoma: A dosimetrical analysis. SECI Oncology Journal, 2023; 11(2): 146-152.